Thermal Expansion Calculator
Correct a measurement to the 20 °C reference temperature
Difference from the 20 °C reference: 10.0 K
Part grows by 11.50 µm
Gauge grows by 11.50 µm
Measurement error from temperature: 0.00 µm
Part size corrected to 20 °C: 99.9885 mm
ΔL = L × α × (T − 20 °C). Coefficients are typical values; use your material certificate for exact figures. When part and gauge are the same material and temperature, the effect largely cancels, which is why gauges and parts should soak together before checking.
Why 20 °C matters
ISO 1 sets 20 °C as the reference temperature for dimensional measurement. A 100 mm steel part measured at 30 °C is about 11.5 µm larger than it is at 20 °C, which can be more than the whole tolerance on a precision bore.
If the part and the gauge are the same material and at the same temperature, most of the error cancels. It returns when they differ, for example an aluminium part checked with a steel gauge, or a gauge straight from a cold store. Our calibration laboratory is held at 20 ± 0.5 °C for this reason.
More: all tools · thread gauges · NABL calibration services